The DLCA NET is a new load cell amplifier with embedded dual port communications including EtherNet/IP, PROFINET, Modbus TCP and EtherCAT. Also included are Rockwell features like EDS File based AOP add on profile, DLR Device Level Ring and PTP time stamping.
The DLCA NET transmits calibrated tension values over the communications to a PLC, HMI or drive to display tension or be used in a tension control loop when not using a MAGPOWR tension control. The DLCA NET is available in 3 mounting options and is available as a single channel version to monitor tension in a single zone with separate left and right load cell inputs or as a dual channel amplifier for 2 separate tension zones.
DLCA-NET Specifications
- Power Supply24 VDC, +/- 10%, 250mA maximum
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from a single tension zone, connected to a left and right input
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from two separate tension zones connected to a channel 1 and 2 input
- Load Cell Excitation5 or 7.5 VDC, 200mADC maximum
- Load Cell Sensitivity1.5 to 100 mV/V, 500 mV maximum
- Display6-digit LED
- MountingDIN 35 Rail
- Operating Temperature0 to 60˚ C32 to 140˚ F
- Storage Temperature-20 to 80˚ C-4 to 176˚ F
- EnclosureIP20
- Certifications CE (EN61326-1)
TUV Mark (UL61010-1)
CAN/CSA-C22.2# 61010-1
CB to IEC 61010-1
RoHS
ODVA Conformant - Sampling frequency2 milliseconds (500 Hz)
- Tension A to D Resolution24 bit (14 bit average)
- Adjustable Filtering0.1 to 100 Hz, or can be turned off for raw data output of 500 Hz
- CommunicationsEtherNet/IP
PROFINET
Modbus TCP and an embedded web server page
EtherCAT - AlarmsTwo programable alarm outputs
30 VDC maximum, 0.4 ADC maximum - Ready to Run AlarmIndicates no errors, ready to operate
30 VDC maximum, 0.4 ADC maximum - Tare Adjustment90% of load cell rating
- Ethernet2 ports (10/100 Mbps)
- Digital Input (re-zero)24 VDC Maximum
5 VDC or 24 VDC slectable threshold - Analog Outputs0 to 10 VDC (2 kohm minimum load)
4 to 20 mADC, 450 ohm maximum load - Reference Meter Output0 to 1 mADC, 1 kohm maximum load
0 to 10 VDC open circuit
DLCA NET-Slim Specifications
- Power Supply24 VDC, +/- 10%, 250mA maximum
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from a single tension zone, connected to a left and right input
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from two separate tension zones connected to a channel 1 and 2 input
- Load Cell Excitation5 or 7.5 VDC, 200mADC maximum
- Load Cell Sensitivity1.5 to 100 mV/V, 500 mV maximum
- MountingDin 35 rail
- Operating Temperature0 to 60˚ C32 to 140˚ F
- Storage Temperature-20 to 80˚ C-4 to 176˚ F
- EnclosureIP20
- Certifications CE (EN61326-1)
TUV Mark (UL61010-1)
CAN/CSA-C22.2# 61010-1
CB to IEC 61010-1
RoHS
ODVA Conformant - Sampling frequency2 milliseconds (500 Hz)
- Tension A to D Resolution24 bit (14 bit average)
- Adjustable Filtering0.1 to 100 Hz, or can be turned off for raw data output of 500 Hz
- CommunicationsEtherNet/IP
PROFINET
Modbus TCP and an embedded web server page
EtherCAT - AlarmsTwo programable
- Ready to Run AlarmIndicates no errors, ready to operate
- Tare Adjustment90% of load cell rating
- Ethernet2 ports (10/100 Mbps)
DLCA NET-IP65 Specifications
- Power Supply24 VDC, +/- 10%, 250mA maximum
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from a single tension zone, connected to a left and right input
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from two separate tension zones connected to a channel 1 and 2 input
- Load Cell Excitation5 or 7.5 VDC, 200mADC maximum
- Load Cell Sensitivity1.5 to 100 mV/V, 500 mV maximum
- MountingWall mount slots
- Operating Temperature0 to 60˚ C32 to 140˚ F
- Storage Temperature-20 to 80˚ C-4 to 176˚ F
- EnclosureIP65
- Certifications CE (EN61326-1)
TUV Mark (UL61010-1)
CAN/CSA-C22.2# 61010-1
CB to IEC 61010-1
RoHS
ODVA Conformant - Sampling frequency2 milliseconds (500 Hz)
- Tension A to D Resolution24 bit (14 bit average)
- Adjustable Filtering0.1 to 100 Hz, or can be turned off for raw data output of 500 Hz
- CommunicationsEtherNet/IP
PROFINET
Modbus TCP and an embedded web server page
EtherCAT - AlarmsTwo programable
- Ready to Run AlarmIndicates no errors, ready to operate
- Tare Adjustment90% of load cell rating
- Ethernet2 ports (10/100 Mbps)
English
Italian

MAGPOWR Engineers have developed software to help you select the best clutch, brake or load cell for your application. Contact us at +1.405.755.1600 to verify sizing or ask questions.
Click here to download the software.
If you click on the link and nothing happens, right click on the download link and choose "open in new tab"